Concrete Column
Tied rectangular column P-M interaction by strain compatibility (ACI 318-19 Ch. 22).
Validation, assumptions & limitations Download validation report (PDF) ↗
This calculator is verified by 4 independent tests comparing its output against closed-form statics, NDS/SDPWS design-standard values and published worked examples. Full case-by-case results are in the PDF report.
Assumptions
- Tied rectangular column; longitudinal bars split equally each face.
- Uniaxial bending; plane sections, eps_cu = 0.003.
- Es = 29,000 ksi; standard ASTM bar areas.
Limitations
- Uniaxial P-M only (no biaxial Bresler check here).
- Slenderness handled by the separate beam-column tool.
- Detailing (tie size/spacing, splices) confirmed separately.
Results are for preliminary design and must be confirmed by a licensed engineer against the current adopted code and project-specific conditions.